Cast Iron Wafer Check Valves Supplier in India — PN10/PN16/ANSI 125 — DN40–DN600 | KELOR
Krishna Industries (KELOR), based in Ahmedabad, Gujarat, supplies Cast Iron Wafer Check Valves (Non-Return Valves / NRV) — single plate and dual plate types — PN10 / PN16 / ANSI 125 pressure ratings — EPDM seat (standard) / NBR / Viton / PTFE / metal seat on request — 1½″ to 24″ (DN40 to DN600) — CI body (IS 210 FG200) — CI or SS disc — conforming to IS 13094 and API 594 — GST invoice — MOQ 10 Nos — Pan India dispatch from Ahmedabad.
Mill Test Report 3.1 can be provided on request from verified vendors. API 598 test certificates, hydro test reports and BIS/ISI marked products arranged on request from BIS-certified vendors. OEM logo and packaging available on bulk orders from verified vendor partners.
⚡ Quick Reference
📧 Get Fast Quotation — Bulk & Project Pricing
Need bulk pricing or technical datasheets? WhatsApp size list, quantity, and seat material preference — competitive pricing within 2 hours.
💬 Get Price on WhatsApp 📩 Get Price by EmailCast Iron Wafer Check Valves — Overview
Cast Iron Wafer Check Valves are non-return valves (NRV) designed to allow unidirectional flow and automatically prevent reverse flow in piping systems. The compact wafer-type design fits easily between standard ANSI, DIN, or BS flanges without requiring its own flanged ends, making it an economical and space-saving solution for water supply, HVAC, fire fighting, irrigation, and general industrial piping systems across India.
KELOR supplies CI wafer check valves from verified and quality-assured vendor partners. These valves are supplied with CI body conforming to IS 210 FG200 grade, precision-machined internals for low pressure drop and quick response, and a range of seat materials to suit different fluid applications. The result is long service life with maintenance-free operation in continuous industrial duty. With sizes from 1½″ to 24″ and three pressure ratings (PN10, PN16, ANSI 125), KELOR covers the full spectrum of CI wafer check valve requirements for Indian projects.
Technical Features
Single Plate vs Dual Plate Wafer Check Valve
CI wafer check valves are available in two disc configurations — single plate and dual plate. Selecting the correct type depends on the application requirements for pressure drop, flow velocity, installation orientation, and cost. Both types share the same wafer body design that fits between flanges, but differ in the disc mechanism and performance characteristics.
| Feature | Single Plate Wafer Check Valve | Dual Plate Wafer Check Valve |
|---|---|---|
| Disc Configuration | One spring-loaded disc hinged at centre | Two spring-loaded discs that open from centre |
| Pressure Drop | Higher — single disc obstructs more flow area | ✅ Lower — dual discs split flow, reduced obstruction |
| Flow Velocity | Suitable for moderate flow velocities | ✅ Suitable for higher flow velocities and pulsating flow |
| Water Hammer | Moderate water hammer on closure | ✅ Reduced water hammer — two lighter discs close faster with less impact |
| Cost | ✅ Lower — simpler construction — standard for water and HVAC | Higher — justified for high-velocity or pulsating flow applications |
| Common Sizes | DN40 to DN300 (1½″ to 12″) | DN50 to DN600 (2″ to 24″) — preferred for larger sizes |
| Best Application | ✅ Water supply, HVAC, fire fighting — standard for most Indian projects | Pump discharge with pulsating flow, high-velocity water mains, large-diameter pipelines |
Technical Specifications
| Parameter | Specification |
|---|---|
| Design Type | Single Plate / Dual Plate Wafer Type |
| Body Material | Cast Iron (IS 210 FG200 / ASTM A126 Class B) |
| Disc Material | Cast Iron (standard) / SS304 / SS316 (optional) |
| Seat Material | EPDM (standard) / NBR / Viton / PTFE / Metal |
| Spring Material | SS316 |
| Hinge Pin | SS316 |
| Pressure Rating | PN10 / PN16 / ANSI 125 |
| End Connection | Wafer Between Flanges (ANSI / DIN / BS) |
| Size Range | 1½″ to 24″ (DN40 to DN600) |
| Media | Water, Air, Oil, Non-Corrosive Fluids |
| Temperature Range | -10°C to +120°C (EPDM) / -10°C to +80°C (NBR) |
| Installation | Horizontal & Vertical (flow upward) |
| Design Standard | IS 13094 / API 594 |
| Testing Standard | API 598 — shell test and seat leakage test |
| MOQ | 10 Pieces |
| HSN Code | 84818090 |
Material of Construction
| Part | Material | Standard |
|---|---|---|
| Body | Cast Iron | IS 210 FG200 / ASTM A126 Class B |
| Disc / Plate | Cast Iron (standard) / SS304 / SS316 (optional) | IS 210 / ASTM A182 (SS) |
| Seat | EPDM / NBR / Viton / PTFE / Metal | Per application specification |
| Spring | SS316 | ASTM A313 |
| Hinge Pin | SS316 | ASTM A276 |
| Body Gasket | EPDM / NBR | Per seat material selection |
📖 Applicable Standards
CI wafer check valves supplied by Krishna Industries (KELOR) conform to the following Indian and international standards:
- API 594 — Wafer and wafer-lug check valves (design requirements)
- API 598 — Valve inspection and testing (shell test and seat leakage test)
- IS 13094 — Cast iron wafer type check valves (Indian standard)
- IS 210 — Grey iron castings (CI body grade FG200)
- ASME B16.5 — Pipe flanges and flanged fittings (ANSI 125 rating)
- ISO 5208 — Industrial valves — pressure testing of metallic valves
Understanding Pressure Ratings — PN10 vs PN16 vs ANSI 125
CI wafer check valves are available in three pressure rating systems that are commonly encountered in Indian project specifications. Understanding the differences between these ratings is essential for procurement teams and piping engineers to ensure correct valve selection:
| Rating | Pressure at Ambient | Flange Standard | Common Use |
|---|---|---|---|
| PN10 | 10 bar (145 psi) | DIN EN 1092-1 | Low-pressure utility — irrigation, non-critical water distribution |
| PN16 | 16 bar (232 psi) | DIN EN 1092-1 | ✅ Standard for Indian water supply, HVAC, fire fighting — most common specification |
| ANSI 125 | ~13.8 bar (200 psi) | ASME B16.5 / B16.42 | Projects following American piping standards — equivalent to PN10–PN16 range |
Standard Dimensions — Single Plate Wafer Type
| Size (NB) | DN (mm) | Face to Face (mm) | Flange OD 150# (mm) |
|---|---|---|---|
| 1½″ | 40 | 38 | 105 |
| 2″ | 50 | 43 | 120 |
| 3″ | 80 | 46 | 150 |
| 4″ | 100 | 64 | 175 |
| 6″ | 150 | 76 | 220 |
| 8″ | 200 | 89 | 270 |
| 10″ | 250 | 114 | 325 |
| 12″ | 300 | 114 | 380 |
| 16″ | 400 | 127 | 480 |
| 20″ | 500 | 152 | 585 |
| 24″ | 600 | 178 | 685 |
Applications in Indian Industries
💧 Water Supply Lines
Installed at pump discharge, distribution headers, and overhead tank inlets in municipal water supply, Jal Jeevan Mission projects, and industrial water treatment. CI wafer check valves with EPDM seat are the standard NRV for Indian water supply systems — economical, reliable, and IS 13094 compliant.
🔥 Fire Fighting Systems
Standard NRV for fire pump suction and discharge, sprinkler risers, and hydrant ring mains. NBC 2016 mandates NRV at fire pump discharge. CI wafer check valves with EPDM seat are NBC-compliant for fire water service. KELOR supplies with test certificates for fire NOC inspections.
🏥 HVAC Pipelines
Chilled water, cooling water, and hot water circuit isolation. The wafer design fits in tight mechanical rooms. Low cracking pressure reduces pump energy consumption. PN16 rating handles the pressure requirements of commercial building HVAC systems.
🌐 Pumping Systems
Pump discharge NRV to prevent backflow and reverse rotation. Critical protection for centrifugal and submersible pumps in water supply, industrial process, and irrigation systems. Spring-loaded design ensures fast closure on pump stop.
🏗 Irrigation Networks
Canal and pipeline isolation for irrigation systems, lift irrigation schemes, and government irrigation department projects. CI body is economical for large-diameter irrigation NRV requirements up to 24″ (DN600). Jal Jeevan Mission compatible.
⚙ Industrial Utilities
General engineering services including cooling water circuits, compressed air lines, process water distribution, and non-corrosive fluid handling. CI body with NBR seat handles oil and general industrial media. For corrosive chemical service, specify SS wafer check valve.
Why Choose KELOR for CI Wafer Check Valves?
Quality Verified
API 598 shell test and seat leakage test performed. Mill Test Report 3.1 can be provided on request from verified vendors. Full material traceability maintained.
Pan India Dispatch
GST invoice with E-Way bill. Dispatch from Ahmedabad within 5–10 working days. Ready stock in common sizes. Export-standard packing for international shipments.
Fast Quotation
WhatsApp size list and quantity — project pricing within 2 hours. Dedicated support for EPC contractors, MEP consultants, and government tenders.
Full Documentation
API 598 test certificate, hydro test report, MTC (EN 10204 Type 3.1), GST invoice. Third-party inspection (TPI) coordination available.
Competitive Pricing
Starting from ₹250/piece. Ex-Works India pricing. Bulk discount on 100+ pieces. 30% advance, balance before dispatch.
Full Size Range
1½″ to 24″ (DN40–DN600) — single plate and dual plate — PN10/PN16/ANSI 125. Supply capacity 2000+ pieces/month.
📈 Pricing & Order Details
Frequently Asked Questions
🔗 Explore More from KELOR
CI Single Plate Wafer NRV SS Wafer Check Valve CI Butterfly Valve — S.G. Iron 3-Piece Flanged Ball Valve Gate Valve Guide SS Grades for Valves Guide 📷 Instagram — KELOR 💼 LinkedIn — KELORKrishna Industries (KELOR) supplies Cast Iron Wafer Check Valves (NRV) — single plate and dual plate — PN10 / PN16 / ANSI 125 — EPDM / NBR / Viton / PTFE / Metal seat — 1½″ to 24″ (DN40–DN600) — CI body (IS 210 FG200) — IS 13094 / API 594 — API 598 tested — MTC — GST invoice — Pan India dispatch from Ahmedabad.
WhatsApp size list, quantity, and seat material for pricing within 2 hours. Starting from ₹250/piece. The standard NRV for water supply, HVAC, fire fighting, and irrigation in India.