Fire and Safety Equipment supplier in Ahmedabad, Gujarat. Complete range — Fire Hydrant System components (IS 5290), Fire Extinguishers (IS 2190 / IS 15683), Fire Sprinkler Systems (IS 15034 / NFPA 13), Fire Alarm and Detection Systems (IS 2189), and…
Fire and Safety Equipment Supplier India | IS 2190 IS 5290 NBC 2016 | KELOR
Price on Request
- KRISHNA INDUSTRIES
- GST No. : 24AKLPP6499B1ZT
- Ahmedabad, Gujarat, India
- Manufacturer, Traders & Wholesale Supplier
- Year of Establishment : Since 1985
- Annual Turnover : Below Rs. 25 Crore Approx.
- Banker : APANI SAHAKARI BANK LIMITED
- Company CEO : Ruchin Panchal
- Constitution of Business : Proprietorship
- Leading Valve Supplier in India covering Maharashtra, Gujarat, Tamil Nadu, Karnataka, Telangana, Delhi NCR, West Bengal, Rajasthan, Madhya Pradesh, Uttar Pradesh, Punjab, Haryana, Andhra Pradesh, Odisha, Chhattisgarh, Jharkhand, Bihar, Kerala, Assam.
- Major Industrial Supply Cities: Ahmedabad, Vadodara, Rajkot, Surat, Mumbai, Pune, Thane, Nashik, Nagpur, Chennai, Coimbatore, Bengaluru, Hyderabad, Delhi, Noida, Gurugram, Faridabad, Kolkata, Jaipur, Indore, Bhopal, Lucknow, Kanpur, Ludhiana, Visakhapatnam.
Description
Fire and Safety Equipment Supplier India | IS 5290 / IS 2190 / NBC 2016 | KELOR Ahmedabad
Supplier: Krishna Industries (KELOR) – Ahmedabad, Gujarat, India
Established: 2017 | GSTIN: 24AKLPP6499B1ZT | IEC: AKLPP6499B
MOQ: 10 Nos | Standards: IS 5290 / IS 2190 / IS 2189 / IS 15034 / NBC 2016
Buyers: Fire Fighting Contractors | MEP Contractors | EPC Buyers | Building Developers
Introduction – Fire and Safety Equipment Supplier India
Krishna Industries (KELOR), based in Ahmedabad, Gujarat, India, is a trusted B2B supplier of Fire and Safety Equipment sourced from verified Indian manufacturers. We supply a complete range of fire protection and industrial safety products — Fire Hydrant System components, Fire Extinguishers, Fire Sprinkler Systems, Fire Alarm and Detection Systems, and Industrial Safety PPE — conforming to IS 5290, IS 2190, IS 2189, IS 15034, NBC 2016 Part 4, and TAC requirements.
Fire protection is not optional in India — it is legally mandated under the National Building Code (NBC) 2016, the Factories Act 1948, local municipal fire department bylaws, and insurance compliance norms. Every industrial plant, commercial building, warehouse, hospital, educational institution, and high-rise residential building in India must install fire safety equipment to specified Indian Standards and obtain fire department approval for occupancy certification. Krishna Industries supplies IS-compliant, BIS-marked, and TAC-approved fire and safety equipment that meets these mandatory requirements.
We supply to fire fighting system contractors, MEP and HVAC contractors, EPC project procurement teams, building developers, government project agencies, plant safety officers, and bulk industrial MRO buyers across Gujarat and PAN India.
Indian Standards and Regulations — Quick Reference for Project Buyers
Every fire safety product in India must meet specific Indian Standards. This is the reference table every fire fighting contractor and MEP project engineer needs when preparing procurement BOMs:
| Product | Indian Standard | Scope | Mandatory For |
|---|---|---|---|
| Landing Valve | IS 5290 | Design, material, dimensions, testing for wet and dry riser landing valves | All high-rise buildings per NBC 2016 — fire department mandatory |
| Fire Hose Coupling | IS 903 | 63mm and 75mm instantaneous couplings for fire hoses | Matching couplings on landing valves and hose reels |
| Fire Hydrant (External) | IS 908 | Pillar and sluice type yard hydrants for external firefighting | Industrial plants, warehouses, large building complexes |
| Fire Hose | IS 636 | Non-percolating woven hose for fire fighting | All fire hose reel and hydrant systems |
| Portable Fire Extinguisher | IS 2190 / IS 15683 | Selection, installation, maintenance / Performance of portable extinguishers | Factories Act, NBC 2016 — all premises |
| Fire Sprinkler System | IS 15034 / NFPA 13 | Automatic sprinkler system design and installation | High-rise buildings, malls, warehouses — NBC 2016 Part 4 |
| Fire Alarm System | IS 2189 | Selection, installation, commissioning of fire detection and alarm systems | All commercial, industrial, and high-rise buildings — NBC 2016 |
| Safety Helmet | IS 4770 / IS 2925 | Industrial helmets — design and performance | Factories Act, construction sites, industrial plants |
| Safety Footwear | IS 15298 | Safety shoes and boots — toe protection, slip resistance | Industrial plants, construction sites |
Important for project buyers: TAC (Tariff Advisory Committee) and state fire departments require BIS-certified products conforming to the above IS standards for fire department approval and occupancy certification. Always confirm BIS marking on fire safety products before purchase — Krishna Industries supplies BIS-marked and TAC-approved products only.
1. Fire Hydrant System — Complete Component Supply
The fire hydrant system is Krishna Industries’ core fire safety product — directly connected to our valve and piping expertise. We supply all components required for a complete fire hydrant system installation conforming to IS 5290, IS 903, IS 908, and NBC 2016 Part 4:
| Component | Standard | Specification |
|---|---|---|
| Landing Valve — Single Outlet | IS 5290 (BIS marked) | CI body, gunmetal internals, 80mm flanged inlet, 63mm IS 903 outlet, PN16 |
| Landing Valve — Double Outlet | IS 5290 (BIS marked) | CI body, gunmetal internals, 100mm flanged inlet, two 63mm IS 903 outlets, PN16 |
| Yard Hydrant Valve (Pillar Type) | IS 908 | CI body, single / double outlet, ground level installation |
| Hose Reel Drum | IS 884 | 25mm x 30m rubber hose, wall-mounted swing-type drum, manual reel |
| Fire Hose | IS 636 | 63mm non-percolating woven hose — 15m per length — with IS 903 couplings |
| Hose Box (Cabinet) | IS 5290 compliant | MS powder-coated red box — single door / double door — for landing valve and hose storage |
| Branch Pipe and Nozzle | IS 903 | 63mm branch pipe with variable / fixed nozzle — 12mm, 16mm, 20mm orifice |
| Gate Valve for Fire Main | IS 14846 / IS 1218 | CI / DI resilient seated — PN16 — main isolation on fire water headers |
| Check Valve (NRV) | IS 5312 | Wafer / dual plate — pump discharge non-return on fire pump headers |
As a valve and piping specialist, Krishna Industries can supply the complete fire hydrant system BOM — landing valves, gate valves, check valves, Y strainers, flanges, pipe fittings, and all accessories — in a single consolidated order with one GST invoice and one dispatch.
2. Fire Extinguishers — IS 2190 / IS 15683
We supply portable and trolley-mounted fire extinguishers for all fire classes — conforming to IS 2190 (code of practice for selection, installation, and maintenance) and IS 15683 (performance requirements for portable fire extinguishers). BIS-certified products only.
| Type | Fire Class | Capacity | Best For |
|---|---|---|---|
| ABC Dry Powder (DCP) | Class A, B, C | 1 kg to 9 kg portable / 25 kg to 50 kg trolley | ✅ General purpose — factories, offices, warehouses — most common in India |
| CO2 (Carbon Dioxide) | Class B, Electrical | 2 kg to 9 kg portable / 22.5 kg trolley | Electrical panels, server rooms, control rooms — clean agent, no residue |
| Water Type | Class A | 9 litres | Ordinary combustibles — paper, wood, textile — NOT for electrical or oil fires |
| Foam (AFFF) | Class A, B | 9 litres to 50 litres | Flammable liquid fires — fuel storage, tanker loading, refineries |
| Clean Agent (HFC-227ea) | Class B, C, Electrical | 2 kg to 6 kg | Server rooms, data centres, heritage buildings — zero residue |
3. Fire Sprinkler Systems — IS 15034 / NFPA 13
Automatic sprinkler systems are mandatory under NBC 2016 for high-rise buildings above 15m, shopping malls, multiplexes, hospitals, and large warehouses. We supply sprinkler system components conforming to IS 15034 and NFPA 13:
- Sprinkler Heads — pendant, upright, and concealed — standard response (68°C, 74°C, 79°C) and quick response — glass bulb and fusible link types
- Alarm Check Valve (Wet Alarm Valve) — automatic flow alarm on system activation
- Deluge Valve — open sprinkler systems for high-hazard areas — oil and gas, paint booths, transformer rooms
- Flow Switch and Pressure Switch — system monitoring and alarm signal
- Sprinkler Pipes and Fittings — galvanised MS pipe and grooved fittings for sprinkler network
- Pre-action System — for data centres and areas where accidental discharge must be prevented
4. Fire Alarm and Detection Systems — IS 2189
Early fire detection under IS 2189 is mandatory in all commercial, industrial, and high-rise buildings per NBC 2016. We supply complete fire alarm system components:
- Addressable Fire Alarm Panel (FACP) — zone-wise alarm identification — 2-loop to 32-loop panels
- Conventional Fire Alarm Panel — cost-effective for smaller buildings and industrial plants
- Photoelectric Smoke Detector — early warning for slow-burning fires
- Ionisation Smoke Detector — fast-burning fires — kitchen, server room areas
- Rate-of-Rise Heat Detector — boiler rooms, kitchens where smoke detectors not suitable
- Manual Call Point (Break Glass) — manual alarm activation at each floor and exit
- Sounder and Visual Indicator (Beacon) — audible and visual alarm output devices
5. Industrial Safety PPE
| PPE Item | Indian Standard | Application |
|---|---|---|
| Safety Helmet | IS 4770 / IS 2925 | Construction, industrial plants, chemical plants, EPC project sites |
| Safety Shoes | IS 15298 | Industrial plants — steel toe protection, slip resistance, chemical resistance |
| Reflective Safety Jacket | IS 15809 | Construction sites, road works, night operations |
| Fire Blanket | BS EN 1869 | Kitchen fires, small localised fires |
| Emergency Exit / Escape Sign | IS 9457 | All commercial and industrial buildings — NBC 2016 mandatory |
| Safety Signages | IS 9457 | Danger, warning, mandatory, and safe condition signboards |
NBC 2016 — Fire Safety Compliance Quick Reference
| Building Type | Wet Riser | Sprinkler | Fire Alarm | Extinguisher |
|---|---|---|---|---|
| Residential above 15m | ✅ Mandatory | Above 45m | ✅ Mandatory | ✅ Mandatory |
| Commercial / Office above 15m | ✅ Mandatory | Above 24m | ✅ Mandatory | ✅ Mandatory |
| Industrial / Factory | Depends on area | High hazard areas | ✅ Mandatory | ✅ Mandatory |
| Warehouse / Logistics | Above 15m height | ✅ Above 500 sqm | ✅ Mandatory | ✅ Mandatory |
| Mall / Multiplex | ✅ Mandatory | ✅ Mandatory | ✅ Mandatory | ✅ Mandatory |
| Hospital | ✅ Mandatory | ✅ Mandatory | ✅ Mandatory | ✅ Mandatory |
Frequently Asked Questions
1. What Indian standards apply to fire safety equipment?
IS 5290 for landing valves, IS 903 for hose couplings, IS 908 for yard hydrants, IS 636 for fire hose, IS 2190 and IS 15683 for fire extinguishers, IS 15034 for sprinkler systems, IS 2189 for fire alarm systems. All must carry BIS certification for fire department acceptance.
2. Is BIS mark mandatory for fire safety equipment in India?
Yes — BIS certification is mandatory under the compulsory certification scheme. Fire departments and TAC surveyors reject non-BIS products during building completion inspection. Krishna Industries supplies BIS-marked products only.
3. What fire safety systems are mandatory for a high-rise building?
Per NBC 2016 Part 4 — buildings above 15m require wet riser with landing valves, fire alarm, and extinguishers as minimum. Sprinkler mandatory for residential above 45m, commercial above 24m, all malls and hospitals. Verify with local fire department and fire consultant for your specific building type.
4. What fire extinguisher for electrical fire?
CO2 fire extinguisher for electrical panels, server rooms, and control rooms — electrically non-conductive, no residue. Never use water or foam on electrical fires.
5. Can you supply complete fire hydrant system BOM?
Yes — landing valves, gate valves, check valves, Y strainers, hose reels, fire hoses, hose boxes, branch pipes, nozzles, and all accessories in a single consolidated order with one GST invoice.
6. What is the difference between addressable and conventional fire alarm?
Addressable fire alarm panels identify the exact detector or call point that activated — zone and device level identification. Conventional panels identify only the zone — group of detectors. Addressable is mandatory for larger buildings and specified in most commercial and industrial NBC 2016 projects.
7. What sprinkler head activation temperature?
68°C standard response glass bulb for most office and commercial areas. 74°C and 79°C for areas with higher ambient temperatures — boiler rooms, kitchen adjacencies. Quick response heads for high-occupancy areas where early activation reduces life safety risk.
8. Do you supply fire safety equipment for refineries?
Yes — foam type AFFF extinguishers, deluge valve systems, foam monitors, and industrial fire hydrant yard networks for high-hazard oil and gas and refinery applications.
9. What is the MOQ?
MOQ is 10 Nos per line item. Complete project BOM quantities welcome with consolidated pricing.
10. Can fire safety equipment be ordered with industrial valves together?
Yes — Krishna Industries consolidates fire safety equipment with industrial valves, flanges, pipe fittings, and fasteners in single orders — one supplier, one GST invoice, one dispatch.
11. Do you assist in product selection for fire department approval?
Yes — we provide technical guidance on selecting IS-compliant, BIS-marked fire safety products that meet local fire department requirements and NBC 2016 specifications for your building type.
12. What delivery timeline for fire safety equipment?
Standard stock items — 3 to 7 working days from Ahmedabad. Bulk project quantities — 7 to 15 working days depending on product type and quantity. Confirm timeline when placing RFQ.
Conclusion
Krishna Industries (KELOR) is a complete Fire and Safety Equipment supplier in Ahmedabad, Gujarat, India — covering Fire Hydrant System components (IS 5290), Fire Extinguishers (IS 2190 / IS 15683), Fire Sprinkler Systems (IS 15034 / NFPA 13), Fire Alarm and Detection Systems (IS 2189), and Industrial Safety PPE — all BIS-marked and TAC-approved — NBC 2016 Part 4 compliant. Fast PAN India dispatch from Ahmedabad.
For fire fighting contractors, MEP contractors, building developers, plant safety officers, and EPC project buyers — contact Krishna Industries (KELOR), your trusted Fire and Safety Equipment supplier in Ahmedabad, Gujarat, India. WhatsApp your product list and project details for bulk pricing within 2 hours.





Reviews
There are no reviews yet.