MS Fabricated Basket Strainer supplier in Ahmedabad, Gujarat. Mild Steel (IS 2062) fabricated body — SS304 / SS316 / MS perforated or wire mesh basket — simplex (single chamber, periodic cleaning) / duplex (dual chamber, continuous operation) / T-type /…
MS Fabricated Basket Strainer Supplier India | Simplex Duplex T-Type | DN25–DN600 | PN10 PN16 | SS304 SS316 MS Basket | Water Cooling Process | KELOR
Price on Request
- KRISHNA INDUSTRIES
- GST No. : 24AKLPP6499B1ZT
- Ahmedabad, Gujarat, India
- Manufacturer, Traders & Wholesale Supplier
- Year of Establishment : Since 1985
- Annual Turnover : Below Rs. 25 Crore Approx.
- Banker : APANI SAHAKARI BANK LIMITED
- Company CEO : Ruchin Panchal
- Constitution of Business : Proprietorship
- Leading Valve Supplier in India covering Maharashtra, Gujarat, Tamil Nadu, Karnataka, Telangana, Delhi NCR, West Bengal, Rajasthan, Madhya Pradesh, Uttar Pradesh, Punjab, Haryana, Andhra Pradesh, Odisha, Chhattisgarh, Jharkhand, Bihar, Kerala, Assam.
- Major Industrial Supply Cities: Ahmedabad, Vadodara, Rajkot, Surat, Mumbai, Pune, Thane, Nashik, Nagpur, Chennai, Coimbatore, Bengaluru, Hyderabad, Delhi, Noida, Gurugram, Faridabad, Kolkata, Jaipur, Indore, Bhopal, Lucknow, Kanpur, Ludhiana, Visakhapatnam.
Description
MS Fabricated Basket Strainer Supplier India | Simplex / Duplex / T-Type / Custom | IS 2062 MS Body | SS304 SS316 MS Basket | DN25–DN600 | PN10–PN16 | Water / Cooling / Process | KELOR
Supplier: Krishna Industries (KELOR) – Ahmedabad, Gujarat, India
Established: 2017 | GSTIN: 24AKLPP6499B1ZT | IEC: AKLPP6499B
MOQ: 10 Nos | Body: IS 2062 MS Fabricated | Basket: SS304 / SS316 / MS
Types: Simplex / Duplex / T-Type / Custom | Sizes: DN25–DN600
MS Fabricated Basket Strainer Supplier in India
Krishna Industries (KELOR), based in Ahmedabad, Gujarat, is a B2B supplier of MS Fabricated Basket Strainers — Mild Steel (IS 2062) fabricated body — SS304 / SS316 / MS perforated or wire mesh basket — simplex (single chamber) / duplex (dual chamber, continuous operation) / T-type / custom fabricated as per drawing — flanged IS 1538 / ASME B16.5 — PN10 / PN16 / PN25 — DN25 (1″) to DN600 (24″) — 20 mesh to perforated 3–6mm hole size — bolted cover or quick-opening cover — drain plug standard — differential pressure gauge connection on request — GST invoice — MOQ 10 Nos — Pan India dispatch from Ahmedabad.
A basket strainer protects pumps, control valves, flow meters, heat exchangers, and other downstream equipment from solid contaminants in the fluid — rust scale, welding slag, sand, algae, debris — by trapping solids in a removable basket. The large basket surface area (3–5 times greater than a Y strainer screen of the same line size) gives basket strainers their key advantages: lower pressure drop, higher dirt-holding capacity, and less frequent cleaning requirement compared to Y strainers in the same service.
Basket Strainer vs Y Strainer — Which to Specify
The choice between a basket strainer and a Y strainer for pipeline protection depends on flow rate, expected dirt loading, cleaning frequency, and installation space. Specifying the wrong type results in either excessive cleaning frequency (Y strainer in high dirt loading service) or wasted cost (basket strainer for clean low-flow service where a Y strainer is adequate).
| Factor | Y Strainer | Basket Strainer |
|---|---|---|
| Body Construction | Cast body — T or Y shape — compact — integral screen in body pocket | ✅ Fabricated MS body — larger volume — removable basket through top cover — greater dirt-holding space |
| Screen / Basket Area | Screen area limited by compact body — small surface area relative to pipe bore | ✅ Basket has 3–5× more filter surface area than Y strainer screen of same line size — lower velocity through basket — lower pressure drop per unit of dirt loading |
| Dirt-Holding Capacity | Limited — screen fills quickly in high dirt loading service — high cleaning frequency required | ✅ High — large basket volume holds significant debris before differential pressure rises — suitable for raw water, cooling water with scale, pump pit water with high solids |
| Cleaning Method | Drain plug removal and flushing (in-line) or screen removal through body (requires partial disassembly) — messy for high solids | ✅ Top cover removed — basket lifted out completely — cleaned off-line at cleaning station — basket reinstalled — clean, simple, no mess in piping area — no partial disassembly of valve or fittings |
| Pressure Drop | Higher — compact screen — higher velocity through screen area — noticeable DP on pump suction | ✅ Lower — large basket area — lower face velocity — minimal DP impact on pump suction head — critical for NPSH-sensitive pump applications |
| Size Range | DN15–DN200 most practical for cast Y strainer | ✅ DN25–DN600 — basket strainer is the correct choice for DN150 and above in utility and water service |
| Installation Space | ✅ Compact — fits in tight pipe racks and valve manifolds — preferred for process plant piping | Larger body — requires more installation space — especially for top cover clearance above pipeline |
| Specify When | ✅ Process lines, instrument protection, pump seal water, chemical dosing — moderate dirt load — DN15–DN150 — where compact installation is important | ✅ Pump suction protection, cooling water systems, raw water, utility water — high dirt load — frequent cleaning required — DN80–DN600 — where low pressure drop is critical for pump NPSH |
Simplex vs Duplex — Operating Decision
The choice between simplex and duplex basket strainer is determined by one question: can the piping system tolerate a 10–20 minute shutdown for basket cleaning, or must flow be continuous at all times?
| Feature | Simplex Basket Strainer | Duplex Basket Strainer |
|---|---|---|
| Chambers | Single chamber — one basket | ✅ Two chambers in parallel — two baskets — three-way diverting valve |
| Cleaning Procedure | Close inlet isolation valve → depressurise → drain → open cover → remove basket → clean → reinstall → pressurise → open valve — system SHUTDOWN 10–20 minutes | ✅ Rotate diverting valve → flow transfers to chamber 2 → chamber 1 depressurised → basket cleaned → chamber 1 refilled → valve rotated back — ZERO PROCESS INTERRUPTION — continuous flow maintained throughout |
| Process Interruption | Yes — periodic shutdown required for each basket cleaning — cleaning frequency determines downtime frequency | ✅ None — designed for continuous operation — basket change-out performed while system runs at full flow |
| Cost | ✅ Lower — single body, one basket, simpler construction — correct for non-critical or standby systems | Higher — dual body, two baskets, diverting valve — justified in continuous process applications where any interruption causes production loss |
| Indian Applications | ✅ HVAC cooling water — standby pump suction — water treatment utility — fire water — process water where periodic shutdown is planned — irrigation pump station | ✅ Critical cooling water for continuous process (reactor jacket cooling, compressor intercooler) — once-through cooling water where any interruption trips the process — fuel oil supply to continuous process furnace — any service where flow interruption is not acceptable |
Basket Material Selection
| Basket Material | Construction | Specify For |
|---|---|---|
| MS Perforated Sheet (painted / epoxy coated) |
IS 2062 MS sheet, perforated, painted or epoxy coated | Coarse filtration — river water intake, raw water pump suction, pump pit water with large debris — economical — shortest basket life in corrosive or chemically treated water |
| SS304 Perforated Sheet | AISI 304 / IS 6911 SS sheet, perforated | ✅ Cooling tower water with chemical treatment (biocide, scale inhibitor), DM water, food support utility — significantly longer basket life than MS in treated water — most common Indian specification for cooling water basket strainer |
| SS316 Perforated Sheet | AISI 316 SS sheet, perforated | ✅ Chloride-rich cooling water, seawater cooling, chemical plant utility water with aggressive chemistry — maximum basket life — specify for coastal industrial installations and offshore-type cooling circuits |
| SS304 / SS316 Wire Mesh | Woven wire mesh — 20 to 200 mesh | Fine particle filtration — instrument protection, control valve upstream, nozzle protection, pump mechanical seal water — mesh size per filtration requirement |
Technical Specifications
| Parameter | Specification |
|---|---|
| Body Material | Mild Steel IS 2062 Gr A / Gr B — fabricated plate and pipe construction |
| Basket Material | SS304 perforated (standard) / SS316 perforated / MS perforated / SS304-SS316 wire mesh |
| Basket Perforation / Mesh | 3mm hole / 5mm hole / 6mm hole (coarse) — 20 mesh (841μ) / 40 mesh (400μ) / 100 mesh (149μ) / 200 mesh (74μ) — specify per application |
| Types | Simplex (single chamber) / Duplex (dual chamber, continuous operation) / T-type (compact horizontal) / Custom as per drawing |
| Cover Type | Bolted flat cover (standard) / Quick-opening hinged cover (frequent cleaning) — gasket: rubber / CAF / PTFE as per service |
| End Connection | Flanged — IS 1538 PN10 / PN16 (standard) / ASME B16.5 Class 150 (on request) |
| Pressure Rating | PN10 / PN16 (standard) — PN25 on request |
| Size Range | DN25 (1″) to DN600 (24″) — DN80–DN400 most common |
| Body Finish | Painted (standard) / Epoxy coated (potable water / DM water) / Hot-dip galvanised (outdoor) |
| Drain Connection | Standard — DN15 BSP drain plug at bottom of body |
| Vent Connection | DN15 BSP vent on cover — for air release on refilling |
| DP Gauge Connection | On request — upstream and downstream DN15 BSP tapping for differential pressure gauge or switch |
| MOQ | 10 Nos (standard sizes) — 1 No (custom fabricated) |
| HSN Code | 84213990 |
Applications in Indian Industries
- Pump suction protection — water and utility systems — MS body SS304 basket simplex DN150–DN400 — installed on pump suction line upstream of pump — traps debris before it reaches pump impeller — large basket area ensures minimal NPSH impact — most critical installation point for basket strainer in any pumping system — simplex acceptable where standby pump allows shutdown for basket cleaning — duplex where no standby pump and continuous pumping is required
- Cooling tower systems — Indian process plant — MS body SS304 perforated basket simplex DN100–DN300 — cooling water supply header strainer — protects heat exchanger tubes, cooling coils, and spray nozzles from scale flakes, algae debris, and corrosion products in recirculating cooling water — SS304 basket resists biocide and scale inhibitor chemicals in treated cooling water — quick-opening cover for frequent cleaning in high fouling cooling circuits
- Power plants — cooling water and condensate systems — MS body SS316 basket duplex DN200–DN600 — river water or sea water cooling inlet strainers — continuous cooling water supply to condenser and heat exchangers — duplex essential as any cooling water interruption trips the turbine — large bore DN400–DN600 basket strainers at intake pump stations — coarse perforated basket (5–6mm holes) at intake, finer 20-mesh in circulating water header
- Sugar mills — Gujarat, Maharashtra, Uttar Pradesh — MS body SS304 basket simplex DN80–DN200 — juice line strainer protecting evaporator heat exchanger tubes — cooling water strainer on vacuum condenser — process water strainer on cane washing — simplex acceptable in sugar mills where crushing season shutdowns are planned — basket cleaned during regular mill stops
- Cement plants and steel plants — MS body MS perforated basket simplex DN150–DN400 — cooling water strainers on kiln cooling circuits, compressor intercoolers, hydraulic oil coolers — heavy industrial utility water with high scale and debris loading — frequent basket cleaning required — quick-opening davit cover for rapid basket change on heavy industrial service
- Water treatment plants — WTP and STP — MS body SS304 basket simplex DN100–DN300 — raw water pump suction protection, filter backwash pump suction, sludge pump suction — coarse perforated basket for raw water with sand and debris — simplex with scheduled basket cleaning during normal plant operation
Related Products — Krishna Industries (KELOR)
- Y Strainer Valve — cast body T or Y strainer — DN15–DN200 — process line protection, instrument protection, pump seal water — compact installation — where basket strainer is too large and dirt loading is moderate
- Duplex Strainer — SS316 inline duplex strainer — for chemical, pharma, and corrosive service where MS body is not suitable and continuous operation is required
- Single Plate Wafer Check Valve (NRV) — install on pump discharge downstream of basket strainer — prevents backflow when pump trips
- Flanged Swing Check Valve — large bore pump discharge NRV — DN80–DN1000 — in the same pump station piping where basket strainer protects pump suction
- Gate Valve — isolation valves on upstream and downstream flanged connections of basket strainer — allow strainer isolation for basket removal without draining entire system
Frequently Asked Questions
1. What is the difference between a basket strainer and a Y strainer — when should I specify basket strainer?
A Y strainer has a cast compact body with a small screen pocket — suitable for moderate dirt loading in process lines and instrument connections. A basket strainer has a larger fabricated body with a removable basket that has 3–5 times more filter surface area than a Y strainer screen of the same pipe size. Specify a basket strainer when: the fluid has high dirt loading (raw water, cooling water with scale, pump pit water), the line size is DN100 and above, low pressure drop on pump suction is important for NPSH margin, or frequent cleaning is required and the basket must be accessible and cleanable quickly without disturbing the pipeline. For DN150 pump suction protection in any Indian water or utility pumping system, a basket strainer is almost always the correct specification over a Y strainer.
2. How do I know when the basket needs cleaning?
The most reliable indication is differential pressure (DP) across the strainer — as the basket fills with debris, pressure drop increases. Specify a differential pressure gauge or DP switch on the strainer (upstream and downstream tapping — available on request) and clean the basket when DP reaches a pre-set limit (typically 0.3–0.5 bar for most utility applications). Without a DP gauge, the basket should be cleaned on a scheduled basis — frequency determined by dirt loading in the first few weeks of operation. A basket strainer that is never visually checked and never cleaned eventually becomes a flow restriction and can damage the pump it is supposed to protect — the drain plug and vent connection on the strainer body allow quick inspection of dirt loading without full cover removal.
3. When should I specify a quick-opening cover instead of a bolted cover?
Specify a quick-opening hinged or swing-bolt cover when basket cleaning is required frequently — more than once per week — and the time required to undo multiple bolts for each cleaning is a significant operational burden. Quick-opening covers (davit arm, hinged with single locking latch, or swing-bolt design) reduce cleaning time from 15–20 minutes for a bolted cover to 3–5 minutes. For most Indian industrial cooling water applications where weekly cleaning is typical, a bolted cover is adequate. For pump pit water or raw river water intake with very high debris loading where daily cleaning is required, quick-opening covers are justified.
4. Can basket strainers be used on pump suction lines?
Yes — basket strainers are the standard pump suction protection device in large bore water and utility piping. The low pressure drop of the basket strainer (compared to a Y strainer) is particularly important on pump suction lines where every bar of suction pressure is needed for NPSH margin. A clogged Y strainer on pump suction can cavitate and damage the pump — the larger basket area of a basket strainer takes much longer to clog to the same DP, giving more time between cleanings and more warning before suction becomes critical. For pump suction protection on DN100 and above, always specify a basket strainer rather than a Y strainer.
5. What is the MOQ?
MOQ is 10 Nos for standard simplex and T-type basket strainers. Custom fabricated sizes and duplex configurations: MOQ 1 No — each unit fabricated to customer drawing or specification. Provide line size, body material, basket material, mesh/perforation size, cover type (bolted/quick-opening), pressure rating, flange drilling standard, and quantity for pricing within 2 hours. For duplex basket strainers: also specify operating pressure, cleaning frequency requirement, and whether diverting valve is to be supplied with strainer body.
Conclusion
Krishna Industries (KELOR) supplies MS Fabricated Basket Strainers for pump suction protection, cooling water systems, raw water, process utility, power plant, sugar mill, cement plant, and water treatment applications — Mild Steel (IS 2062) fabricated body — SS304 / SS316 / MS perforated or wire mesh basket — simplex (single chamber) / duplex (dual chamber, continuous operation) / T-type / custom fabricated as per drawing — flanged IS 1538 / ASME B16.5 — PN10 / PN16 / PN25 — DN25 (1″) to DN600 (24″) — bolted or quick-opening cover — drain plug — DP gauge connection on request — GST invoice — Pan India dispatch from Ahmedabad. WhatsApp line size, basket material, mesh size, cover type, pressure rating, and quantity for pricing within 2 hours.



Reviews
There are no reviews yet.