2/2 Way Direct Acting Solenoid Valve Supplier in India — Brass / SS / CI | KELOR
Krishna Industries (KELOR), based in Ahmedabad, Gujarat, supplies 2/2 Way Direct Acting Solenoid Valves — brass, stainless steel, and cast iron body — NBR, Viton, EPDM, PTFE seal options — 24V DC, 230V AC, 110V AC coil — 0 to 16 Bar pressure range — 1/4″ to 2″ — 100% ED continuous duty — water, air, oil, steam, and gas media — MOQ 10 Pcs — Pan India dispatch from Ahmedabad.
Mill Test Report 3.1 can be provided on request from verified vendors. Hydrostatic test certificates provided with every order. GST invoice with HSN 8481 80 90 for all solenoid valve dispatches.
? Quick Reference
?? On This Page
- Overview — 2/2 Way Direct Acting Solenoid Valve
- How a Direct Acting Solenoid Valve Works
- Body Material Selection
- Seal Material Selection
- Coil Voltage Guide — AC vs DC
- Technical Specifications
- Applications in Indian Industries
- Direct Acting vs Pilot Operated
- Why Choose KELOR
- Vendor Partner Registration
- Commercial Information
- Related Products
- Frequently Asked Questions
2/2 Way Direct Acting Solenoid Valve — Overview
Krishna Industries (KELOR) supplies the 2/2 Way Direct Acting Solenoid Valve — an electromechanically operated ON–OFF valve that controls the flow of water, air, oil, steam, and gas in industrial piping and automation systems. The designation “2/2 way” refers to the valve having two ports (one inlet, one outlet) and two switching positions (open and closed). The term “direct acting” means the electromagnetic force generated by the coil directly lifts the plunger to open the valve seat — no minimum pressure differential is required for operation, making these valves suitable for zero-pressure-start applications, vacuum lines, and low-pressure systems where pilot operated valves cannot function.
KELOR supplies solenoid valves in three body materials to cover the full range of industrial service conditions. Brass body valves are the most economical choice for water, air, and general-purpose applications. Stainless steel body valves provide corrosion resistance for chemical, food-grade, and outdoor installations. Cast iron body valves are specified for steam, oil, and heavier industrial services requiring robust construction. Each valve is pressure-tested for leakage at the factory and supplied with the correct coil voltage as specified by the buyer. KELOR supports OEM, bulk, and export orders with consistent quality, GST-compliant documentation, and Pan India dispatch from the Ahmedabad warehouse.
How a Direct Acting Solenoid Valve Works
A direct acting solenoid valve uses the electromagnetic force generated by an energised coil to directly lift a plunger (or piston) away from the valve seat, opening the flow path from inlet to outlet. When the coil is de-energised, a return spring pushes the plunger back onto the seat, closing the valve. Because the electromagnetic force acts directly on the plunger without relying on line pressure assistance, the valve can operate at zero inlet pressure — a critical advantage over pilot operated designs in vacuum, gravity drain, and low-pressure applications. The coil is rated for 100% ED (continuous duty), meaning it can remain energised indefinitely without overheating during normal plant operation.
Coil Energised
When electrical power (24V DC or 230V AC) is applied to the coil, a magnetic field is generated around the coil assembly. The magnetic force attracts the plunger (armature) upward, compressing the return spring.
Plunger Lifts
The plunger lifts off the valve seat, opening the flow path between inlet and outlet. Process media (water, air, oil, steam, or gas) flows through the valve body from inlet port to outlet port.
Valve Open (ON)
While the coil remains energised, the valve stays fully open. 100% ED rating allows continuous energisation for unlimited duration. Media flows continuously at rated pressure and flow capacity.
Coil De-energised (OFF)
When power is removed, the return spring forces the plunger back onto the valve seat, sealing the flow path. The valve closes tightly, and media flow stops completely. The cycle can repeat at the rated frequency.
? Key Advantage — Zero Pressure Differential Operation
Unlike pilot operated solenoid valves that require a minimum pressure differential (typically 0.5 to 1 bar) to open, a direct acting solenoid valve opens using only electromagnetic force — it operates at zero inlet pressure. This makes it the correct selection for vacuum applications, gravity-fed drain lines, vent-to-atmosphere circuits, and any installation where the upstream pressure may be at or near zero bar. The trade-off is that direct acting valves have lower flow capacity (Cv/Kv values) compared to pilot operated valves of the same pipe size, because the electromagnetic force must overcome both the spring force and the media pressure acting on the plunger area.
Body Material Selection
| Body Material | Standard | Specify For | Not For |
|---|---|---|---|
| Brass | Forged Brass / CZ122 | Water, compressed air, neutral gas, light oil, general industrial automation — most economical option — standard for pneumatic and water control systems — good machinability and corrosion resistance for non-aggressive media | Steam above 120°C, chloride water, seawater, concentrated acid or alkali — brass dezincifies in aggressive chloride environments |
| Stainless Steel | SS304 / SS316 / CF8M | Chemical process, food and beverage, pharmaceutical, outdoor installations, marine coastal, corrosive media — excellent corrosion resistance — suitable for wash-down environments — long service life in aggressive conditions | Cost-sensitive applications where brass is adequate — stainless steel commands a price premium of 2 to 3 times over brass for the same size |
| Cast Iron | GG25 / FC250 | Steam service, heavy oil, industrial gas, high-temperature air, robust mechanical protection applications — high-pressure rating for steam — strong and rigid body for industrial plant environments | Water with chlorides, corrosive chemical, food-grade or pharmaceutical — cast iron corrodes in acidic or chloride-containing service |
?? Body Material Selection Rule
For water, compressed air, and pneumatic automation: brass body — the most common and economical choice that covers the majority of Indian industrial applications. For chemical, food, pharmaceutical, or outdoor installations: stainless steel body — the corrosion resistance justifies the premium cost in aggressive media environments. For steam, heavy oil, and rugged industrial service: cast iron body — provides the mechanical strength and temperature rating required for steam plant applications.
Seal Material Selection
The seal material (also called the seat seal or diaphragm) determines the valve’s compatibility with specific media, temperature range, and chemical resistance. Selecting the correct seal material is as important as selecting the correct body material — the wrong seal will cause leakage, rapid degradation, and premature valve failure. KELOR supplies 2/2 way direct acting solenoid valves with four standard seal material options to cover the full range of industrial media and temperature requirements:
| Seal Material | Chemical Name | Max Temperature | Best For | Not For |
|---|---|---|---|---|
| NBR | Nitrile Rubber | 90°C | Water, compressed air, light oil, mineral oil, hydraulic oil, neutral gas — most economical seal — standard for water and pneumatic service | Steam, ozone, ketones, chlorinated hydrocarbons — NBR hardens and cracks above 90°C |
| Viton (FKM) | Fluorocarbon Rubber | 180°C | Hot oil, chemical resistance, fuels, acids, aromatic hydrocarbons — wide chemical compatibility — suitable for chemical process and petrochemical service | Steam (continuous above 150°C), low-temperature applications below -20°C — Viton is expensive, only specify when chemical resistance is required |
| EPDM | Ethylene Propylene Diene | 150°C | Hot water, steam (intermittent), glycol, brake fluid, mild chemical — excellent water and weather resistance — good for HVAC and hot water systems | Mineral oil, petroleum-based fluids, fuels — EPDM swells and degrades in oil and petroleum media |
| PTFE | PTFE (Teflon) | 200°C | Steam (continuous), aggressive chemical, corrosive media, high-purity applications — widest chemical resistance of all seal materials — food and pharmaceutical grade | Applications requiring soft seating — PTFE has higher leakage tendency compared to rubber seals due to its rigidity |
? Common Seal Selection Mistake
The most common seal selection error is using NBR seals for steam service. NBR degrades rapidly above 90°C and will fail within days on steam lines operating at 150 to 180°C, causing dangerous leakage. For steam service, always specify PTFE seals (continuous duty up to 200°C) or Viton seals (intermittent duty up to 180°C). Similarly, never use EPDM for oil service — EPDM swells dramatically in petroleum-based fluids. For oil and fuel service, specify NBR for light oil or Viton for hot oil and aggressive hydrocarbons.
Coil Voltage Guide — AC vs DC
The solenoid coil converts electrical energy into the magnetic force that operates the valve. Coil voltage must match the available power supply at the installation site. KELOR supplies solenoid valves with factory-fitted coils in the following standard voltages. Voltage selection is permanent — a coil rated for one voltage cannot be used on a different voltage without immediate damage. Always confirm the control voltage at the installation site before placing an order.
| Voltage | Type | Typical Application | Key Consideration |
|---|---|---|---|
| 24V DC | Direct Current | PLC-controlled automation, DCS systems, electronic control panels, battery backup circuits, solar-powered installations — the most common voltage in modern industrial automation | Stable, silent operation. Coil resistance is fixed. No inrush current. Polarity sensitive — confirm + and – terminals. Standard for all PLC-based control systems. |
| 230V AC | Alternating Current | Direct switch control from plant power supply, relay panels, motor control centres, older plant installations — standard Indian industrial mains voltage | Inrush current on energisation is 5 to 10 times holding current. Coil hums during operation. Not polarity sensitive. Standard for relay-based control systems. |
| 110V AC | Alternating Current | Imported machinery, US-standard equipment, specific OEM requirements, dual-voltage installations with step-down transformers | Same operating characteristics as 230V AC but at half the voltage. Less common in Indian plants but required for certain imported equipment and OEM specifications. |
?? DC vs AC Coil — Operational Differences
DC coils provide stable, silent operation with consistent force output — the electromagnetic force is constant regardless of the AC cycle position. DC coils are polarity sensitive and must be connected with correct positive and negative terminals. AC coils produce a characteristic hum during operation due to the alternating magnetic field (50 Hz or 60 Hz mains frequency) and have a higher initial inrush current that drops to holding current once the plunger is seated. AC coils are not polarity sensitive and can be connected either way. For PLC and electronic control systems, 24V DC is the industry standard. For direct switch control from the plant power supply, 230V AC is the standard in India.
Technical Specifications
| Parameter | Specification |
|---|---|
| Valve Type | 2/2 Way Direct Acting — Normally Closed (NC) |
| Body Material | Brass / Stainless Steel (SS304 / SS316) / Cast Iron (GG25) |
| Seal Material | NBR / Viton (FKM) / EPDM / PTFE |
| Coil Voltage | 24V DC / 230V AC / 110V AC |
| Pressure Range | 0 to 16 Bar (0 to 232 psi) |
| Size Range | 1/4″ (DN8) to 2″ (DN50) |
| Operating Media | Water, Air, Oil, Steam, Gas, Neutral Chemical |
| Duty Cycle | 100% ED (Continuous Duty) |
| Operating Temperature | -10°C to +200°C (depending on seal material) |
| Coil Protection | IP65 (dust-proof, water jet protection) |
| Connection Type | Female Threaded (BSP / NPT) / Flanged |
| MOQ | 10 Pieces per specification |
Applications in Indian Industries
2/2 way direct acting solenoid valves are among the most widely used automation components in Indian industry. Their simple ON–OFF operation, fast response time, and compatibility with PLC and electronic control systems make them the standard choice for automated fluid control across virtually every industrial sector. KELOR supplies solenoid valves to the following industries from the Ahmedabad warehouse with Pan India dispatch capability.
Water Treatment & RO Plants
Reverse osmosis plants, demineralisation (DM) plants, sewage treatment, and effluent treatment use solenoid valves for automated flush cycles, backwash control, chemical dosing line isolation, and product water divert valves. Brass body with EPDM seals is the standard combination for water treatment applications.
Industrial Automation & PLC
Pneumatic actuator control, cylinder sequencing, air dryer sequencing, and process valve automation use 24V DC solenoid valves controlled by PLCs and DCS systems. The 2/2 way direct acting design provides fast, reliable switching with zero minimum pressure requirement — essential for pneumatic circuits that start from zero pressure.
Steam Tracing & Heating
Steam tracing lines for process pipe freeze protection, steam jacket heating, and autoclave systems use solenoid valves with cast iron body and PTFE seals for temperature control. The direct acting design operates reliably even when steam pressure drops during low-demand periods — a critical reliability advantage for freeze protection systems.
Compressed Air & Pneumatics
Compressor unload, air receiver drain, pneumatic conveying, dust collection pulse-jet cleaning, and instrument air supply use brass body solenoid valves with NBR seals. 24V DC coils are standard for PLC-controlled compressor sequencing, while 230V AC coils are used for direct switch control on smaller systems.
Direct Acting vs Pilot Operated Solenoid Valve
Understanding the difference between direct acting and pilot operated solenoid valves is critical for correct valve selection. Both types are 2/2 way (two ports, two positions) and perform ON–OFF flow control, but they operate on fundamentally different principles and are suited to different applications. Selecting the wrong type can result in valve failure, unreliable operation, or unnecessary cost.
| Parameter | Direct Acting | Pilot Operated |
|---|---|---|
| Operating Principle | Electromagnetic force directly lifts plunger from seat | Electromagnetic force opens pilot passage; line pressure assists lifting the main valve |
| Min. Pressure Differential | Zero — operates at 0 bar inlet pressure | 0.5 to 1 bar minimum required |
| Flow Capacity (Cv) | Lower — limited by electromagnetic force and plunger area | Higher — line pressure assists, allowing larger orifice for same coil |
| Response Time | Fast — typically 10 to 50 milliseconds | Moderate — typically 50 to 500 milliseconds |
| Best Applications | Vacuum, low-pressure, gravity drain, steam tracing, vent-to-atmosphere, zero-pressure-start circuits | High-flow water, compressed air mains, gas distribution, process piping with consistent pressure |
| Size Range | Typically 1/4″ to 2″ | Typically 1/2″ to 4″ and larger |
Why Choose KELOR
Pressure-Tested Valves
Every solenoid valve is factory-tested for leakage at rated pressure before dispatch. Test certificates provided with every order for QA documentation and project compliance.
High-Quality Coils
100% ED rated coils with IP65 protection. Class H insulation for extended thermal life. Correct voltage marked on every coil enclosure for safe and reliable installation.
Fast Dispatch
Standard brass valves dispatched within 3 to 5 working days from Ahmedabad warehouse. SS and CI valves dispatched within 7 to 10 working days. Express dispatch available for urgent orders.
OEM Branding Support
KELOR supports OEM buyers with neutral packing and customised labelling. Bulk orders with buyer’s brand name and part number printed on packaging are supplied on request.
Export Supply
KELOR supplies solenoid valves for export orders with export-grade packing, commercial invoices, and shipping documentation. Export pricing varies by destination and quantity.
Full Documentation
GST invoice, test certificates, and Mill Test Report 3.1 (on request from verified vendors) provided with every order. Project BOM documentation customised to buyer requirements.
Vendor Partner Registration
KELOR is a sourcing and supply company — not a manufacturer. We source solenoid valves from verified vendor partners who manufacture to our quality requirements. If you are a solenoid valve manufacturer looking for a reliable distribution and supply partner in India, we invite you to register as a KELOR vendor partner. We offer long-term supply agreements, consistent order volumes, and Pan India market reach through our established customer base in industrial automation, water treatment, steam systems, and OEM segments.
?? Become a KELOR Vendor Partner
We are looking for vendor partners who can manufacture 2/2 way and 3/2 way solenoid valves in brass, stainless steel, and cast iron body materials with consistent quality, competitive pricing, and reliable delivery schedules. To register, send your company profile, product catalogue, quality certifications (ISO 9001), and sample pricing via WhatsApp or email. Our procurement team reviews vendor applications within 5 working days.
Register as a Vendor Partner
Submit your company details and product catalogue to explore long-term supply opportunities with KELOR.
Register on WhatsApp Register by EmailCommercial Information
?? Pricing & Ordering
?? B2B Buying Checklist
When placing an order for 2/2 way direct acting solenoid valves, provide the following specifications for accurate pricing and correct supply: (1) Body material — brass, stainless steel, or cast iron. (2) Size — 1/4″, 1/2″, 3/4″, 1″, 1-1/4″, 1-1/2″, or 2″. (3) Seal material — NBR, Viton, EPDM, or PTFE. (4) Coil voltage — 24V DC, 230V AC, or 110V AC. (5) Connection type — BSP threaded, NPT threaded, or flanged. (6) Quantity per specification. (7) Delivery location. WhatsApp or email these details for pricing within 2 hours during business hours.
Related Products
Frequently Asked Questions
Request a Quote for 2/2 Way Direct Acting Solenoid Valve
Send your specifications — body material, size, seal, voltage, quantity — for pricing within 2 hours.
Get Price on WhatsApp Get Price by Email?? Connect with KELOR
Instagram — @kelorvalves LinkedIn — Krishna Industries (KELOR) WhatsApp — +91 93135 43530 Email — hello.krishnavalves@gmail.comKrishna Industries (KELOR) supplies industrial-grade 2/2 way direct acting solenoid valves from verified vendor partners in brass, stainless steel, and cast iron body materials with NBR, Viton, EPDM, and PTFE seal options and 24V DC, 230V AC, and 110V AC coil voltages. Every valve is pressure-tested before dispatch and supplied with full documentation including GST invoice, test certificates, and MTR 3.1 on request. With 15,000+ solenoid valves supplied to automation integrators, OEMs, and industrial buyers across India, KELOR provides consistent quality, competitive pricing, and reliable Pan India dispatch from the Ahmedabad warehouse. WhatsApp or email your specifications for pricing within 2 hours.